The Goodwinch Turbo Power Controller

IMPORTANT
i) Auxiliary battery must NOT be earthed to vehicle chassis or have anything else connected to it.
ii) +ve Red for Remote must come from Turbo Unit (not the main +ve feed to the Winch
iii) Winch Solenoid –ve feed must come from Turbo Unit (remove existing Solenoid Earth)
iv) A safety cut out switch MUST be fitted between the +ve Solenoid connection on the Controller and the Winch.
v) DO NOT INSTALL UNDER THE BONNET OR CLOSE TO THE EXHAUST SYSTEM OR ANY OTHER HEAT SOURCE. Best mounted vertically with the connector block at the top.

turbo-power-controller-sonnection-strip

For more information about this product click here

Telephone: 01363 82666

Fax: 01363 82782

Email:sales@goodwinch.com

Goodwinch Ltd, David Bowyer's Off Road Centre, East Foldhay, Zeal Monachorum, Crediton, Devon, England, EX17 6DH